Pass-Type Biparting doors are used in
hoistways that have short floor to floor heights.
Floor to floor height must be equal to
or exceed the landing door height plus 610mm (24 in.). Required overhead
height and pit depth are the same as regular bi-parting doors.
Required car clearance between the elevator platform and building sill
is 170mm (6.75 in.).